Field Attachable Non-Skive Hose Assembly

Field Attachable Non-Skive Hose Assembly

ASSEMBLY INSTRUCTIONS FOR:

RYCO FIELD ATTACHABLE COUPLINGS WITH RYCO NON-SKIVE HOSE.
USE ONLY RYCO T1A, T1D, T2A, T2D, TXA2D, TJ2D, RQP1, RQP2, RQP5, T5, M2 and RT72 SERIES HOSE.

  STEP ONE
  Cut hose to length required using a cut-off saw.
  Ensure hose is cut squarely.
  Clean hose bore.
 
  STEP TWO
  Lubricate outer cover.

 
  STEP THREE
  Screw anti-clockwise until hose bottoms in ferrule.
  Ease back between 1/2 and 3/4 of a turn.
 
  STEP FOUR
  Liberally oil insert and inside of hose.
 
  STEP FIVE
  Screw insert clockwise right into ferrule using a continuous motion.
  Do not allow hose to turn during operation.
  SPECIAL NOTES:

1. For T1A and T1D Hose in sizes -20, -24, -32
    In these sizes, K Series Ferrules are not available and A Series
    Field Attachable Couplings must be used.
    The cover of hose must be skived at ends.
    Refer to page 325 for assembly instructions.
2. For T2A, T2D and RQP2 Hose in sizes -24, -32
    In these sizes, L Series Ferrules are not available and
    B Series Field Attachable Couplings must be used. The cover
    of hose must be skived at ends.
    Refer to page 325 for assembly instructions.
3. Field Attachable Couplings should not be used on RQP1
    and RQP2 Hose at maximum working pressure when
    temperature exceeds 121°C (250°F).
    Field Attachable Couplings may be used on RQP1 and
    RQP2 Hose at over 121°C (250°F) but at reduced
    working pressure.
    Contact RYCO for more information.